Skip to content

Fire safety design and fire strategy

Fire safety design from concept to detailed design: fire safety class, fire compartments, evacuation and firefighting access. Level 6 experts in Estonia.

Service

Fire safety design from concept to detailed design

The fire safety section of a building design shows how the building meets the essential fire safety requirements: load-bearing capacity is maintained for the required time, the spread of fire and smoke is limited, people can evacuate safely and the rescue team has the conditions it needs (Estonian Regulation No. 17 on fire safety requirements for buildings, § 3).

We prepare the fire safety design at every stage, together with a fire strategy that the architect, structural engineer and building services engineers can work from. The earlier fire safety is built into the design, the less has to be redone later.

What the fire safety design covers

  • Building use class and fire safety class (TP1, TP2 or TP3) with justification
  • Fire compartments and fire resistance of load-bearing and separating structures
  • Reaction to fire of internal and external surface materials
  • Evacuation: exits and escape routes, travel distances and widths
  • Fire safety installations: fire alarm, emergency lighting, smoke control and, where required, sprinklers and rising mains
  • Firefighting access, entry to the building and, where required, a fire brigade information point
  • Deviations from the regulation’s limit values and their analytical justification
  • For buildings with a shelter requirement, the shelter solution under Government Regulation No. 50

For whomArchitects, lead designers, project managers and developers

What you getFire safety report and drawings at every design stage, plus answers to the reviewers’ and Rescue Board’s questions

Input dataArchitectural design (site plan, floor plans, sections), building use, net enclosed area and number of occupants

When to involve usAt concept stage; at the latest when preliminary design starts

How we work

1

Concept and fire strategy

We define the use class and fire safety class, fire compartments, evacuation principles and firefighting conditions, so the architectural solution and budget can be fixed.

2

Preliminary design

We prepare the report and drawings that form the basis for the building permit application and the other disciplines. The Rescue Board approves the design before the building permit is issued (Fire Safety Act § 5(1)).

3

Main design

We refine the solutions with the structural and services engineers: fire resistance of openings, penetrations and fire safety installation requirements.

4

Detailed design

We add the details needed for construction and procurement. Construction-phase fire safety consulting is agreed separately.

Questions and answers

What is a fire safety class and how is it determined?

Estonian buildings fall into fire safety classes TP1 (fire-resistant), TP2 (fire-retardant) and TP3 (combustible). The class depends on the building’s use, room uses, number of storeys, height, area, number of occupants and fire load density. Limits on storeys, height and occupants for TP2 and TP3 buildings are set out in Annex 2 of Regulation No. 17. The class directly affects the choice of structures and materials, and therefore construction cost.

What is a fire strategy?

A fire strategy is prepared at concept stage and fixes the building’s fire safety principles: use class and fire safety class, fire compartments, evacuation, firefighting conditions and required fire safety installations. The architect and engineers work from it, and it forms the basis of the preliminary fire safety design.

What if the design does not meet the regulation’s limit values?

Under § 4 of Regulation No. 17, compliance with the essential fire safety requirements must then be demonstrated analytically. This is done by a person holding a Level 6 Fire Safety Expert certificate. Our experts hold this qualification and assess at concept stage whether and how a deviation can be justified.

Is a fire safety design needed when an existing building is altered?

Yes. When a building is reconstructed or extended, the reconstructed or extended parts must meet current requirements (Regulation No. 17, § 55(5)). If an extension increases the number of storeys, all storeys must be brought into compliance or fire safety must be demonstrated analytically (§ 5(4)).

Who approves the fire safety design?

The Estonian Rescue Board approves the building design before a building or occupancy permit is issued (Fire Safety Act § 5(1)). For single-family houses, summer houses and garden houses the local authority may decide without the Rescue Board if it can assess the requirements itself (§ 5(11)). We answer the Rescue Board’s and expert reviewers’ questions on the design we prepared. We do not carry out expert reviews ourselves.

How much does it cost?

The price depends on the size and use of the building and the scope of work. Send us a description of the building and any existing drawings and we will prepare an exact quote.

Based on Regulation No. 17 on fire safety requirements for buildings and the Fire Safety Act (Riigi Teataja, current versions, in Estonian). Content verified 19 Nov 2026, responsible: Priit Pääso.

Let’s talk about your project

Send a short description and drawings if available. We will define the scope and prepare a quote. See what to include in our checklist (PDF).

Direct contact

+372 507 8370
info@fireplan.ee

Quotes and proposals: Priit Pääso, CEO

Fireplan OÜ
Veskiposti 2 (Electra building), 10138 Tallinn, Estonia
Registry code 14552826
VAT EE102177763

What to include

  • Site address and building use
  • Number of storeys, height and net enclosed area
  • Design stage and desired deadline
  • Drawings in PDF or DWG, if available