Skip to content

Sheltering plan and shelter space

Existing buildings meeting the shelter criteria need a sheltering plan by 1 July 2027. We prepare the plan and find a shelter space.

Who and by when

A sheltering plan is mandatory for buildings that meet the shelter criteria under the Estonian Crisis Situations and National Defence Act and Annex 1 of Government Regulation No. 50.

  1. 1 Jul 2027Buildings with an occupancy permit that meet the shelter criteria must have a sheltering plan (Crisis Situations and National Defence Act § 185(13)).
  2. Occupancy permitBuildings without an occupancy permit, including new buildings with a shelter requirement, prepare the plan when applying for the permit.
  3. 1 Jul 2028If a building with an occupancy permit has no shelter, a shelter space is adapted where possible (§ 185(14)). Buildings without a permit: when applying for it.

A sheltering plan is required even if sheltering in the building is not possible. In that case the plan describes how building users act in an immediate threat. If you would rather build a shelter than adapt a shelter space in an existing building, we design that too.

What a sheltering plan contains

  • General sheltering arrangements: whether users can shelter, how they move and how they are expected to act in a threat
  • A layout of the shelter or shelter space
  • How the shelter or shelter space is brought into use, stage by stage
  • Where there is no shelter: an assessment of sheltering options and planned actions with deadlines
  • Evacuation arrangements: the route to the shelter space and out of it, the emergency exit
  • Measures for quick and safe sheltering: preparing the room, supplies and signage
  • The person responsible for sheltering; the plan is approved by the owner or the apartment association board and reviewed at least once every five years
  • For a shelter: the maintenance and inspection procedure and recorded results
Shelter space sign: orange square with a blue triangle, the word VARJUMISKOHT and the information panel AVALIK (public)VARJUMISKOHTAVALIK
Sign colours and dimensions: Government Regulation No. 50, Annex 2

Shelter spaces and signage

A shelter space is a structure or part of one, or a temporary structure, adapted for sheltering and protecting at least from objects scattered by an explosion. Under § 18 of the Regulation it is fully or partly below ground or on the ground floor, is intended for stays of up to 12 hours, and where possible provides at least 0.75 m² per person. A shelter space may hold up to 180 people in a residential building and up to 1,000 in other buildings. Adequate air exchange and access to a toilet are required; a shelter space over 15 m² also needs a separately located emergency exit route.

Shelters and shelter spaces are marked under Annex 2 of the regulation: an orange square with a blue equilateral triangle and the word “VARJUMISKOHT”. For public places the information panel says “AVALIK” (public); for non-public places it shows the address. Signs are used in three sizes as needed: in public space (short side as A2, visible up to 100 m), on façades (A4, up to 50 m) and on entrance, protective or shelter space doors (A6, up to 15 m). The sign is installed as soon as a shelter space has been adapted – for a non-public space at least on its door; direction signs are installed when the space is being made ready.

For Tallinn apartment associations

Crisis preparedness grant for adapting a shelter space

The City of Tallinn supports apartment associations in adapting a common room of an apartment building into a shelter space. The conditions are set by the Tallinn City Council regulation on crisis preparedness grants for apartment associations.

On 12 November 2026 the City Council adopted amendments to the regulation. The new conditions apply once published in Riigi Teataja; until then the current version applies.

The application includes

  • The apartment association’s decision on the works
  • A sheltering plan with a layout
  • A list of planned activities, works, equipment and supplies with a budget

How we help

  • We prepare the sheltering plan and layout under Government Regulation No. 50
  • We prepare the list of activities and budget for the application
  • We are an independent consultant: not your association’s manager or property manager

Verified 16 Nov 2026: Tallinn City Council regulation No. 30 of 12 June 2025 (RT IV, 20.06.2025, 7), current version.

How we help

1

Building assessment

We inspect the building and assess whether and where a shelter space can be adapted, and for how many people.

2

Shelter space solution

We propose the room and the adaptations needed, taking into account the structure and budget.

3

Sheltering plan

We prepare the layout, the procedure for bringing the space into use and the responsibilities.

4

Signage and handover

We prepare a signage plan under Annex 2 and hand the plan over to the owner or apartment association board.

Based on the Crisis Situations and National Defence Act (§§ 96–97, § 185) and Government Regulation No. 50 (version in force from 1 Oct 2026). Content verified 31 Oct 2026, responsible: Priit Pääso.

Let’s talk about your project

Send a short description and drawings if available. We will define the scope and prepare a quote. See what to include in our checklist (PDF).

Direct contact

+372 507 8370
info@fireplan.ee

Quotes and proposals: Priit Pääso, CEO

Fireplan OÜ
Veskiposti 2 (Electra building), 10138 Tallinn, Estonia
Registry code 14552826
VAT EE102177763

What to include

  • Site address and building use
  • Number of storeys, height and net enclosed area
  • Design stage and desired deadline
  • Drawings in PDF or DWG, if available